Plasterboard ceilings allow you to conceal services and integrate lighting, but the most important decisions are made before covering the framework. Simply marking light fitting locations is not enough: you need to coordinate their installation depth, fixings, electrical controls, duct layout and access to equipment requiring servicing.
The key question before installing the boards: do all components fit, are they properly secured and will they remain accessible? The following list of decisions will help you prepare for a discussion with your ceiling installer, electrician and ventilation specialist.
1. Start with a coordinated ceiling plan
Everything may look suitable on separate lighting and ventilation plans, but combining them can reveal a light fitting positioned at a duct or an access hatch overlapping an LED recess. It is therefore worth marking the locations of light fittings, diffusers, ducts, hatches and ceiling levels on a single coordinated plan.
Record not only distances from walls, but also positions relative to furniture: the dining table, kitchen island and cupboards. For example, a light fitting in the centre of a room will not necessarily be above the table if its position changes later.
- Specify the finished ceiling level in each room and any locally lowered sections.
- Mark the locations of light fittings, lighting recesses, diffusers and access hatches.
- Coordinate these components’ positions with the framework and service routes.
- Record the plan version and who must approve subsequent changes.
2. What light fitting details should you provide?
A photo of a light fitting or a description such as “round recessed LED” is not sufficient installation information. Different models may have different housing depths, cut-out sizes, power supply equipment and heat dissipation requirements.
It is best to select the exact model before finalising the ceiling construction. If the selection is not yet complete, agree on acceptable installation conditions with the specialists and clearly note that the final model will still need to be checked.
- Model and instructions: provide the manufacturer’s technical specifications and installation documents.
- Cut-out and installation depth: not only the visible diameter of the light fitting matters, but also the space needed for its housing and connections.
- Weight and fixings: particularly relevant for pendant lights.
- Power supply: whether it is integrated or external, where it will be located and how it will be replaced.
- Controls: whether the model is dimmable and which control device it is compatible with.
- Insulation conditions: whether contact with insulation is permitted and which installation conditions must be followed.
These details must be assessed for the specific product. For example, the Philips CoreLine Downlight gen5 model specifications provide specific installation parameters and control features. The specifications for one model are not universal requirements for all ceilings.
3. Ceiling height and fixings are not just finishing considerations
The ceiling drop is determined by assessing the entire system planned for the space above the boards: framework, light fittings, ducts, their connections, insulation and the space needed for maintenance. A uniform drop throughout the home is therefore not always possible or necessary.
If the desired ceiling height is incompatible with the selected equipment, a decision must be made before installation: change the equipment, service route or lighting layout, or allow for a locally lowered section. The framework or ducts must not be altered without approval simply to accommodate a light fitting.
The fixing point for a pendant light must be planned in advance. Do not assume that plasterboard can support any weight of light fitting. The fixing solution depends on the light fitting, additional loads and the selected ceiling system. The Knauf D11 ceiling systems document assesses additional loads according to the conditions of the specific structure; in certain cases, they are fixed directly to the structural slab.
4. Concealed equipment must remain accessible
It is easy to conceal a power supply or control module, but it is important to plan for its replacement without dismantling the finished ceiling. Agree with the electrician on its location, the manufacturer’s operating conditions and the access method. If access is planned through the light fitting opening, check that the equipment can actually be removed and replaced.
Access to ventilation equipment must also meet servicing needs. Being able to reach a filter does not necessarily mean there will be enough space to remove another component. The Komfovent DOMEKT installation instructions distinguish between access requirements for routine maintenance and for component repair or replacement.
Choose an access hatch based on the location of the component to be serviced, the required opening and the properties of the ceiling construction. A small, visually discreet hatch alone is not a good solution if the planned work cannot be carried out through it.
5. Checklist before closing up the ceiling
This checklist can be used as a shared coordination sheet when installing plasterboard ceilings. It is a tool for coordinating work, not a substitute for an engineering design or mandatory inspections.
| What to coordinate | What to record before installing the boards |
|---|---|
| Ceiling height | Finished levels and locally lowered sections. |
| Component layout | A coordinated plan of light fittings, ducts, diffusers, recesses and hatches. |
| Light fitting details | Models, instructions, cut-outs, installation depth and weight. |
| Fixings | Fixing solutions for pendant lights and other additional loads. |
| Lighting controls | Lighting groups, switch locations and dimming compatibility. |
| Maintenance access | How power supplies, control modules and equipment requiring servicing will be accessed. |
| Inspection | Who checks the electrical, ventilation and ceiling construction work, and who coordinates closing up the ceiling. |
| Documentation | Photos of concealed components and their locations marked on the plan. |
| Scope of responsibilities | Who cuts openings, installs hatches, connects equipment and carries out the final finishing. |
Take photos that clearly show the room and component positions, and mark important locations on the plan. They help with locating things later, but do not replace specialist inspections.
6. When is a designer needed?
Not every issue can be resolved by moving a light fitting. Consult a designer in the relevant discipline when a solution changes structural loads, the operation of a building services system or properties specified in the design.
- Large or uncertain additional loads are planned, and the fixing solution has not been approved.
- Changes to the framework, hanger layout or fixings to the structural slab are proposed.
- Openings and hatches are being installed in a structure subject to fire resistance, acoustic or airtightness requirements.
- A lack of space requires changes to ventilation routes or other design solutions.
- The selected equipment does not fit the planned installation or maintenance space.
Electrical installation safety, connections and required inspections must be assessed by a qualified electrical specialist. A layout plan approved by the client is not confirmation of technical suitability.
7. What should you include in an enquiry and check in the estimate?
For your enquiry, prepare a floor plan, desired ceiling levels, a list of light fittings and any available information about building services. In the estimate, list framework and board installation, recesses, cutting openings, hatches, additional fixings, finishing and equipment connections separately. This will make it clearer whether the estimate covers only the ceilings or related work as well.
Also agree on how changes to a model or location will be coordinated after the plan is approved: who will check compatibility and how any additional work will be assessed.
When planning interior finishing in Vilnius, you can submit this information to Namų Statybai with your enquiry. The company provides services in Vilnius and Vilnius district. The price must be assessed based on the specific project and scope of work.
Research sources
- Plasterboard installation in Vilnius from 12 €/m²: price
- Plasterboard installation in Vilnius | Partitions and ceilings
- Plasterboard Ceiling Installation in Vilnius | APDAILA24
- Philips CoreLine Downlight gen5, 9.8 W, D150 mm, 1200 lm | Signify
- D11 Knauf board ceilings
- INDOOR Installation Instructions FULL GLOW RC380 G
- 3. MECHANICAL INSTALLATION
- REVO airtight/dust-tight 12,5 | Knauf
Prepared using AI and research into public sources. General information does not replace an individual design and a specialist’s assessment.